Last week I attended a customer who had just moved into a very old farm-house just the other side of Hempstead. The new occupier informed me that the property had stood empty for a long time before they had purchased it. By all accounts the previous occupant had not used the two very large inglenook chimneys for a very long time.

Both these chimneys had a hood and register plate configuration and both came with two inspection hatches each. However, this is were the good news ended, both chimneys which were in excess of 10 meters tall and 2 meters wide were completely full of nest material from top to bottom. To complicate meters and make the nest removal more difficult, the inspection hatches for both register plates were very small indeed and were as one plate was reasonably accessible at eye level, the second plate was below hip level.

In both instances I was able to clear the nests using a combination of the pigs tail tool and rods, and power sweeping with the metal flail. The flail is very good at breaking up the interlocking integrity of the nest, whereas the pigs tail is very good for latching on to the nest material and pulling it down the chimney. It was then a process of physically dragging the twigs and other material through the small inspection hatches and carrying it outside in trugs. One of the photographs shows this very process, with a portion of the removed nest having just been pulled through the register plate.

The customer requested that I put all the removed nest material just outside the house on a patio. As you can see there was rather a substantial amount of this, as it formed a small mountain over 6 feet in height. Needless to say it took me a whole day to clear both chimneys and that was working consistently without a break through the day. A monster effort I think you will agree? I certainly slept well that night!



My name is Paddy McKeown, I am a retired police officer (Detective Sergeant – Metropolitan Police), turned chimney sweep. I have completed training with ‘The Guild of Master Chimney Sweeps’, and Rod Tech UK (Power Sweeping).


I considered the best way to sweep this problematic chimney was to power sweep it using liner rods and brush. I did this and found that after every three rods (the chimney was 9 and a half meters tall), the stove was full of tar deposits and had to be cleaned out manually using a large trug and small shovel. I carried on this process until the entire flue had been swept and I had removed one and a half trugs full of tar from the stove. I was then able to tidy up and finish cleaning the stove using the vacuum before putting it back together again. Upon discussing the operation of the stove with the customer I discovered that in the intervening year he had altered his burning habits. He had started using a lot more coal and had taken to stocking the stove up prior to bed time and closing it right down to keep it in for the morning. The customer was tactfully and appropriately advised regarding the operation of his appliance and was pointed to the Guild of Master Sweeps ‘burn right campaign – 